TCL 2575DI指示灯亮,二次不开机故障解决方案
故障现象: 三无(灯亮)机芯: 飞利浦解码OM88**(大屏幕)
机型: 2502D,2516B,2516D,2516DI,2516BI,2580DB,2510G,AT2575,
2575D,2515DZ,2580GI,2580G,2588DB,2511DI,2511D,2511DR,
2511DZ,2575DI,AT2515DZ,AT2590I,AT2590,AT2580D,AT2575D,
AT2575DI,AT2575DZ,AT2575F,AT2588D,AT2539,2939D,2939DR,
2965D,2989D,2913D,2975,2956D,2927D,2915DZ,2988DB,
2916D,2988D,2980G,2980GI,2980DB,2975D,2910G,2910DZ,
2910D,2911,2911D,2911DI,2911DZ,2980D,2988DF,2988DI,2975DI,
AT2975D,AT2980D,AT2980DB,2539D,2539DR,2539DI,3406D,
3433D,3433DZ,3409D,3416,3416D,3416DI,3418D,3416D(F),
3438D,3480GI,3488GI,3460D,3488D,34D106,AT3480DZ,AT3486DI
,AT3460D,AT3416D(F),AT3488DZ,2988G,2988D-F,2911Z,AT2990,
AT2915DZ,AT2990I,AT2975F,AT2975I,AT2988D,AT3480GI,3811DI,
2589D,AT2556,AT2988,AT2988DB,AT2956B,AT2911DZ,AT2915,
AT2939,AT2956,AT2975Z,AT2986Z,AT2575I,AT2586,3488BD,
AT3486DZ
检修过程: 机型:2980G 故障现象:指示灯亮,二次不开机 分析与检修:通电测主电源电压正常,测OM8838(40)脚+1.2V不正常,(41)脚电压+3V不正常,将(41)断开还是不能起振,在二次开机时 注意到行包内有两个“喀叭”声,万用表测与行激励有件都正常,将OM8838换后,故障不能排除,试行输出变压器后修复。
故障板名称: 主板
故障元件位号:OM8838
处理措施:更换OM8838
图片: 无
学习学习!{znds14}{znds14}